Rotronic HC2-ICxxx

The ROTRONIC industrial probe is especially suitable for high temperatures and demanding industrial environments. It measures humidity and temperature and calculates the dew/frost point.

Description

Suitable for Heavy Industrial Applications with Through Wall Installations



The ROTRONIC industrial probe is especially suitable for high temperatures and demanding industrial environments. It measures humidity and temperature and calculates the dew/frost point.

Applications
Production environments, high temperatures, industrial manufacturing, drying processes, climatic chambers

Features

  • Range of application: -100…200 °C / 0…100 %rh
  • Digital interface (UART) and scalable analog outputs, 0…1 V
  • Standard output scaling: 0…1 V = -40…60 °C / 0…100 %rh
  • Adjusted at 23 °C and 10, 35, 80 %rh

Specifications

Probe typeIndustrial probe
DimensionsØ15 x 100 mm / Ø15 x 250 mm / Ø15 x 400 mm / Ø15 x 550 mm / Ø15 x 700 mm
Weight230 g / 260 g / 290 g / 330 g / 350 g /
Operating range-100…200 °C / 0…100 %rh
Accuracy at 23 ±5 °C±0.8 %rh / ±0.1 K
Accuracy w. adjustment profile “standard”>at 23 °C / 10, 35, 80 %rh ± 0.8 %rh / ± 0.1 K
Measuring range-100…200 °C (short-term peak load) / 0…100 %rh
Power supply / Power consumption3.3 V ± 0.1V / ~4.5 mA
Long-term stability
Humidity sensorHygromer IN-1
Temperature sensorPT100 1/3 DIN Class B
Probe protectionFilter carrier, brass nickel plated
Filter cartridgedepending on the application, order separately
Response time t 63
Allowed wind speed3 m/s
Psychrometric calculationsDew or frost point
Reproducibility Airchip
Exploitation softwareROTRONIC HW4
Probe adjustment by software1 Point & multipoint %rh & °C
Firmware updateWith internet and HW4 software
User informationfrom Software HW4 (devicemanager)
Data processing via HW4with interface cables
Device Protection by passwordYes
Type of output signals2 x 0…1 VDC
Analogue outputs scaleable by the userYes
Analog output signal (standard)0…1 V = 0…100 %rh; 0…1 V = -40…60 °C
Digital output signal (standard)UART
Service InterfaceUART
Reverse voltage protectionMechanically in the connector
Sensor frame for %rh and °C sensorYes
Max. cable lengthUp to 5 m with passive cable. Up to 100 m with active cable.
Probe materialPEEK
FDA/GAMP compatibilityFDA 21 CFR Part 11 and GAMP compatible

Documentation

[fontawesome icon=”fa-download” circle=”yes” size=”13px” iconcolor=”” circlecolor=”” circlebordercolor=”” rotate=”” spin=”no” animation_type=”0″ animation_direction=”down” animation_speed=”0.1″ animation_offset=”” alignment=”left” class=”” id=””] Datasheet (PDF)

Go to Top