Rotronic HC-HP28

Price on request Request a quote

Insteekbare sensor voor het meten van verpakte bulkmaterialen

Category:

Description

Plug-in sensor for measuring packed bulk materials

The plug-in sensor is suitable for measurements in bulk materials, bricks, concrete, etc. Het meet vochtigheid en temperatuur en berekent het dauwpunt / vriespunt.

Applications
10 mm insertion probe: measurement in dusty bulk materials such as flour, sugar, etc.

Features.
• Range of application: -40… 85 ° C / 0… 100% RV
• Digital interface (UART) and scalable analogue outputs, 0… 1 V
• Standard output scaling: 0… 1 V = -40… 60 °C / 0… 100% r.h.
• Adjusted to 23°C and 10, 35, 80% RH

Documentation

Brochure wateractiviteit Rotronic HC-HP28

Specifications

Accuracy at 23 ±5 °C ± 0.008 aw / 0.8 %rh / ±0.1 K
Nauwkeurigheid w. afstelprofiel “standaard” bij 23 °C / 10, 35, 80 %Rh ± 0,8 %Rh / ± 0,1 K
Probe type Insertion probe
Operating range -40…85 °C / 0…100 %rh
For use with HygroLab C1, HP23-AW-A
Range of application -40…85 °C (-40…185 °F) / 0…100 %RH
Power supply 3.2…5 VDC, calibrated at 3.3 VDC, current: ~4.5 mA
Long-term stability <1 %rh / year
Humidity sensor Hygromer IN-1
Temperature dependence 0.001 K/K, 0.0002 aw/K
Temperature sensor PT100 1/3 DIN Class B
Filter type Sintered steel with 5 μm pore size
Response time t 63 <20 s, with filter
Allowed wind speed 40 m/s, with filter
Psychrometric calculations Dew or frost point
Measurement interval 1 s
Reproducibility Airchip <0.02 %rh / 0.01 K
Start-up time 1,5 s
Exploitation software ROTRONIC HW4
Probe adjustment by software 1 Point & multipoint %rh & °C
Software Update With internet and HW4 software
User information from Software HW4 (devicemanager)
Data processing via HW4 with interface cables
Device Protection by password Yes
Analogue outputs scaleable by the user Yes
Analog output signal (standard) 0…1 V = 0…100 %rh; 0…1 V = -40…60 °C
Digital output signal (standard) UART
Type of output signals 2 x 0…1 VDC
Enclosure material POM
IP protection rating IP50
Material Stainless steel DIN 1.4305 (probe), POM (handle)
Max. cable length Up to 5 m with passive cable. Up to 100 m with active cable.
Probe material Stainless steel 1.4305 (V2A)
Reverse voltage protection Mechanically in the connector
Service Interface UART
FDA / GAMP FDA 21 CFR part 11 / GAMP5
FDA/GAMP compatibility FDA 21 CFR Part 11 and GAMP compatible
CE / EMC conform 2007 / 108 / EG
Dimensions HC2-HP28: Ø10 x 280 mm
Weight 200 g

    Cart0
    There are no products in the cart!
    Continue shopping
    0