Rotronic HC2-IExxx-M

Price on request Request a quote

This screw-in sensor from Rotronic is available with a 1/2 “G or 1/2 “NPT thread. The sensor can withstand temperatures of -50..200°C and a pressure of up to 100 bar / 1450 PSI.

Description

This screw-in sensor from Rotronic is available with a 1/2 “G or 1/2 “NPT thread. The sensor can withstand temperatures of -50..200°C and a pressure of up to 100 bar / 1450 PSI.

This metal industrial sensor from Rotronic is made for high temperatures, demanding industrial environments and applications where hygiene plays an important role. It measures humidity and temperature, and calculates dew point.

Applications

Food industry, pharmaceutical industry, drying processes, industrial production processes

Features.

  • Application range: -100…200 °C, (screw-in sensor; -50…200 °C) / 0…100 %RH
  • Digital interface (UART) and scalable analogue outputs, 0…1 V
  • Standard scalable outputs: 0…1 V = -40…60 °C / 0…100 %RH
  • Adjustable to 23 °C and 10, 35, 80 %RH

Specifications

Probe type Screw-in probe
Weight 290 g
Operating range -100…200 °C / 0…100 %rh
Accuracy at 23 ±5 °C ±0.8 %rh / ±0.1 K
Accuracy w. adjustment profile “standard” bij 23 °C / 10, 35, 80 %Rh ± 0,8 %Rh / ± 0,1 K
Power supply / Power consumption 3.3 V ± 0.1V / ~4.5 mA
Long-term stability
Humidity sensor Hygromer IN-1
Temperature sensor PT100 1/3 DIN Class B
Probe protection Filter carrier, brass nickel plated
Filter cartridge depending on the application, order separately
Pressure Pressure-resistant to 100 bar / 1450 PSI
Response time t 63
Allowed wind speed 3 m/s
Psychrometric calculations Dew or frost point
Connection thread of probe 1/2″ G / 1/2″ NPT
Reproducibility Airchip
Exploitation software ROTRONIC HW4
Probe adjustment by software 1 Point & multipoint %rh & °C
Firmware update With internet and HW4 software
User information from Software HW4 (devicemanager)
Data processing via HW4 with interface cables
Device Protection by password Yes
Type of output signals 2 x 0…1 VDC
Analogue outputs scaleable by the user Yes
Analog output signal (standard) 0…1 V = 0…100 %rh; 0…1 V = -40…60 °C
Digital output signal (standard) UART
Service Interface UART
Reverse voltage protection Mechanically in the connector
Max. cable length Up to 5 m with passive cable. Up to 100 m with active cable.
Probe material Stainless steel 1.4305 (V2A)
Probe cable material FEP, black
Enclosure material Stainless steel 1.4305 (V2A)
FDA/GAMP compatibility FDA 21 CFR Part 11 and GAMP compatible

Documentation

Brochure Hygroclip 2 – Rotronic HC2-IExxx-M

    Cart0
    There are no products in the cart!
    Continue shopping
    0