Setra 267

Price on request Request a quote

These units sense gauge and differential pressure and are offered with a high level 5 VDC or 10 VDC output as well as a 4-20 mA output. The Model 267 is available with an optional LCD display for convenient viewing of pressure reading.

Please click HERE to configurate your 267.

Description

These units sense gauge and differential pressure and are offered with a high level 5 VDC or 10 VDC output as well as a 4-20 mA output. The Model 267 is available with an optional LCD display for convenient viewing of pressure reading.

Specifications

Electrical Output, Voltage 0 to 5 VDC
0 to 10 VDC
Bidirectional Voltage Output at Zero Mid-range of specified output
Excitation (for 0-5 VDC) 9 to 30 VAC/9 to 42 VDC
Excitation (for 0-10 VDC) 11 to 30 VAC/13 to 42 VDC
Electrical Output, Current 4 to 20 mA
Bidirectional Current Output at Zero 12 mA
Min. loop supply voltage 9 + 0,02 x
Max. loop supply voltage 30 + 0,004 x
Accuracy
(RSS Method)
±1.0% FS (±0.4% FS & ±0.25% FS,
±1% FS, ±0.5% FS optional w/Cal. Cert.)
Type of Pressure Very Low Differential
Media Typically air or similar non-conducting gases
Option LCD Display
Thermal Effects
Compensated Range °C +5 to +65°C
%FS/°C zero/span shift ±0.06°C zero and span combined

    Cart0